
heating - How to wire multiple 240V, 20A electrical baseboard heaters ...
Jan 22, 2019 · I have two baseboard heaters to install on a 240V, 20A circuit. One heater is 1500w and the other is 2000w. From my panel, I leave the 20A breaker with 12/2 wire to reach the first …
Removing baseboard heater/heating loop and purging air
Mar 13, 2023 · I need to rip a baseboard heater out: the cabinet, the copper piping, everything. There is no longer a need to heat that room (reasons: outside the scope of this question). This is fuel oil with …
water circulating heating - Using PEX for baseboard run - Home ...
Jan 6, 2014 · Yes. In fact, I had to do this exact same thing in a house in MN that had baseboard copper freeze and burst in an attic. I ended up replacing the cooper between the boiler and the baseboards …
New baseboard heaters with central AC - thermostat wiring help
Jun 17, 2024 · The baseboard heaters in the 3 bedrooms are each controlled by their own thermostat (one per room), and they also work fine. The issue is with the baseboard heaters in the living room. …
What is the effect on baseboard heating capacity of running the return ...
Jan 30, 2021 · Baseboard radiators can be installed with the return pipe running within the baseboard enclosure itself. While this is a configuration explicitly supported by manufacturers I can't find any …
basement - How high can baseboard heaters be installed? - Home ...
Apr 1, 2024 · I'm trying to do a basement loop to heat up my basement. Can I install a hot water baseboard at approx. 12" from the floor?
Installing 4 baseboard heaters on a 20A double pole circuit
Nov 6, 2023 · 1 I am looking for some help with configurations on installing 4 baseboard heaters on a 20 amp double pole breaker with 12/2 wires. My current set up is all four baseboard heaters are hooked …
heating - How can I efficiently heat a bonus room above a detached ...
Dec 17, 2013 · To run "quick air heating" and "slower radiant floor" off the same system, you make use of a couple of mixing valves so that the floor can run at a lower fluid temperature, while the …
plumbing - Should a circulator pump be installed on the supply or ...
I currently have a forced hot water heating system with 3 zones, all of which have the circulator pump on the supply side of the line. I need to install a 4th zone and am being told that putting the circulator on …
hvac - Is there harm in using my mini-splits in conjunction with my hot ...
The baseboard thermostat isn't next to the mini-split, so it might turn on if the other rooms on that floor dip below 60°. On the first floor, I'm thinking to primarily use the radiant heat, but if we're in the …